Insulating glass dew point meter

Overview

The detector is based on

GB/T11944-20

12 "Insulating Glass Standard" test dew point method is made, using main control semiconductor refrigeration, compressor cooling auxiliary heat dissipation, digital display temperature, with simple operation and intuitive display.



two,

Insulating glass dew point meter

Technical Parameters

1,

Power: 500W

2,

Power supply requirements: AC 220V

3,

Temperature measurement accuracy: 0.5

°C

4,

Minimum temperature: -60 ° C



three,

Insulating glass dew point meter

Instructions

1

Insert the power plug into the power socket, first press the cooling button to turn on the auxiliary cooling for 10 minutes, then turn the main power switch on.

2, the system works, automatically adjust the temperature according to the set temperature (-60 ° C, -55 ° C, -50 ° C -45 ° C, -40 ° C)

.

3. When the temperature reaches the standard required temperature, the system will automatically alarm for 10 seconds, then start timing according to the set time (test time). After the set time is over, the system will automatically alarm again. The experiment ends (the first alarm represents the arrival of the work) Working temperature, the second alarm represents the test is completed).

4. After the test is completed, turn off the power switch first, then turn off the auxiliary cooling (

1, 4 items must be strictly observed, auxiliary cooling can not be closed at will during the test)

.

※The hollow glass dew point meter has two sets of refrigeration equipment. The main control is cold for the semiconductor refrigeration film and the auxiliary refrigeration is the compressor. The main control cooling is controlled by the meter and the auxiliary cooling is manually controlled by the cooling button. It is necessary to assist the cooling in advance for 10 minutes. (The auxiliary cooling and the main control cold power switch are independent respectively.) Please operate according to the requirements. Otherwise, the customer is responsible for the consequences caused by improper operation.



four,

Insulating glass dew point meter

About parameter setting

1. Setting of time parameters: the left side is the working time, the right side is the alarm time, and the unit is adjustable.

2. Setting of temperature parameters

a, the main control temperature setting: press

”

SET

”

Key, temperature display table, the lower row of digital tube is shining, press

”

>

”

Key, move the cursor to the corresponding position of the digital tube, and then press

”

∧

”

,

"

∨

”

The temperature can be modified by pressing the key. After the modification is completed, press the “SET” button again to complete the save. (The master value is one decimal place)

b, alarm temperature setting: press

”

SET

”

After 3 seconds, enter the parameter setting state and continue to press

”

SET

”

Key, find the LOAL item setting item (the alarm value is an integer).

Note: The LOAL value and the master temperature value should be set consistently. The LOAL value should follow the master temperature value each time the master temperature is changed.


Insulating glass dew point instrument after-sales service:

1. All products sold by our factory are guaranteed for one year, free of charge during the warranty period (except for malfunctions or damage caused by human factors or irresistible natural phenomena).

2. Users can consult technical questions through after-sales calls and get a clear solution.

3. When the user has performance failure during normal use, the company promises the above warranty service. Other than that,

If the national applicable laws and regulations clearly stipulate otherwise, the company will comply with relevant laws and regulations.

4. During the warranty period, paid maintenance services will be implemented in the following cases;

(1) Damage caused by man-made or irresistible natural phenomena;

(2) malfunction or damage caused by improper operation;

(3) Failure or damage due to modification, disassembly, and assembly of the product;

(4) The “After-sales Service Commitment” on this page was not returned within one month.


Insulating glass dew point meter picture: Insulating glass dew point meter