December 19 news, according to technology website BGR reported that Samsung has abandoned the lawsuit in Germany seeking to ban iPhone 4S.
Samsung has been suing Apple iPhone 4S for infringing its 3G communications related patents in the hope of seeking to ban the sale of Apple’s iPhone 4S. However, Samsung has recently discovered that Apple’s iPhone product has obtained a patent license from Qualcomm, and Samsung has therefore waived the continued prosecution of Apple in Germany. .
However, although Samsung gave up the lawsuit, Apple would not be too good, Motorola recently filed a lawsuit against Apple in the German Mannheim District Court and won, Apple iPhone and iPad is likely to still face a ban on sales.
Samsung has been suing Apple iPhone 4S for infringing its 3G communications related patents in the hope of seeking to ban the sale of Apple’s iPhone 4S. However, Samsung has recently discovered that Apple’s iPhone product has obtained a patent license from Qualcomm, and Samsung has therefore waived the continued prosecution of Apple in Germany. .
However, although Samsung gave up the lawsuit, Apple would not be too good, Motorola recently filed a lawsuit against Apple in the German Mannheim District Court and won, Apple iPhone and iPad is likely to still face a ban on sales.
Control cable is a kind of cable. It is used for control and monitoring circuits and protection circuits with AC rated voltage of 450V/750V and below. Shielded control cables are widely used in power plants and power stations due to their good shielding performance. They are intended to be laid indoors, in cable trenches, in pipelines, directly buried, in shafts and other fixed places that can withstand greater mechanical tension.
Feature
1. DC rated current Uo/U is 450/750V2. The maximum allowable long-term operating temperature of the cable electrical conductor is 70 ℃.
3 The working temperature during cable laying shall not be lower than 0 ℃. If the natural environment temperature is lower than 0 ℃, the cable shall be heated.
4 The strongly recommended allowable bending radius of cable is below:
The unarmoured cable shall not be less than 6 times of the cable diameter;
Armored cable or copper foil shielded cable shall not be less than 12 times of cable diameter;
The shielded Flexible Cable shall not be less than 6 times of the cable diameter.
5 Productive cable model 2-61 cores
6 Control cables are generally laid in rooms, cable trenches, pipelines and other fixed sites.
Copper Conductor PVC Jacket Control Cable,Armoured Control Cable,Multi Core Control Cable,Sheathed Control Cable
Ruitian Cable CO.,LTD. , https://www.rtlinecable.com